Download Print this page

INVT Goodrive350-19 Series Operation Manual page 419

Vfd for crane
Hide thumbs Also See for Goodrive350-19 Series:

Advertisement

Goodrive350-19 Series VFD for Crane
Bit
12
(when P90.04=1)
13
Positioning reached
When "67: Function parameter mapping" is used, it must be used together with P14.48, and
P14.60–P14.70.
Function
code
Channel selection for
P14.48
mapping between PZDs
and function codes
Mapped function code of
P14.60
Mapped function code of
P14.61
Mapped function code of
P14.62
Mapped function code of
P14.63
Mapped function code of
P14.64
Mapped function code of
P14.65
Mapped function code of
P14.66
Mapped function code of
P14.67
P14.68
Mapped function code of 0x0000–0xFFFF
Name
Brake status
Name
sent PZD2
sent PZD3
sent PZD4
sent PZD5
sent PZD6
sent PZD7
sent PZD8
sent PZD9
Short description of communication PZD
Value
11
Space voltage vector control
0
1
0
1
Description
0x00–0x12
Ones place: Channel for mapping
function codes to PZDs
0: Reserved
1: Group P15
2: Group P16
Tens place: Save function at power off
0: Disable
1: Enable
0x0000–0xFFFF
Set the function code address to be
mapped. For example, if the parameter to
be mapped is P94.39, set it to 0x5E27.
0x0000–0xFFFF
0x0000–0xFFFF
0x0000–0xFFFF
0x0000–0xFFFF
0x0000–0xFFFF
0x0000–0xFFFF
0x0000–0xFFFF
-407-
State/Description
Brake closed
Brake released
Positioning not reached
Positioning reached
Setting
0x11
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000

Advertisement