Goodrive350-19 Series VFD for Crane
Function
Name
code
Running frequency
P07.33
at present fault
Ramp reference
P07.34
frequency at
present fault
Output current at
P07.35
present fault
Output current at
P07.36
present fault
Bus voltage at
P07.37
present fault
Temperature at
P07.38
present fault
Input terminal
P07.39
status at present
fault
Output terminal
P07.40
status at present
fault
Running frequency
P07.41
at last fault
Ramp reference
P07.42
frequency at last
fault
Output voltage at
P07.43
last fault
Output current at
P07.44
last fault
Description
93: AI2 disconnection fault (E-AI2)
94: AI3 disconnection fault (E-AI3)
95: EtherNet IP communication timeout fault
(E-EIP)
96: No upgrade bootload (E-PAO)
97: Second channel encoder disconnection
(Enc2o)
98: SSI position deviation fault (ENCPI)
99: SSI position upward limit (E-PUP)
100: SSI position downward limit (E-Pdn)
101: Fault of instant stop at load change (E-CL)
0.00Hz–P00.03
0.00Hz–P00.03
0–1200V
0.0–6300.0A
0.0–2000.0V
-20.0–120.0° C
0x0000–0xFFFF
0x0000–0xFFFF
0.00Hz–P00.03
0.00Hz–P00.03
0–1200V
0.0–6300.0A
-198-
Function parameters
Default Modify
0.00Hz
0.00Hz
0V
0.0A
0.0V
0.0° C
0x0000
0x0000
0.00Hz
0.00Hz
0V
0.0A

Advertisement