Goodrive350-19 Series VFD for Crane
Function
Name
code
Upper limit of
P00.04
running frequency
Lower limit of
P00.05
running frequency
Setting channel of A
P00.06
frequency
command
Setting channel of B
P00.07
frequency
command
Description
The upper limit of the running frequency is the
upper limit of the output frequency of the VFD,
which is lower than or equal to the max. output
frequency.
When the set frequency is higher than the
upper limit of the running frequency, the upper
limit of the running frequency is used for
running.
Setting range: P00.05–P00.03 (Max. output
frequency)
The lower limit of the running frequency is the
lower limit of the output frequency of the VFD,
When the set frequency is lower than the lower
limit of the running frequency, the lower limit of
the running frequency is used for running.
Setting range: 0.00Hz–P00.04 (Upper limit of
running frequency)
Note: Max. output frequency ≥ Upper limit of
frequency ≥ Lower limit of frequency
0: Keypad digital
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDIA
5: Simple PLC program
6: Multi-step speed running
7: PID control
8: Modbus/Modbus TCP communication
9: PROFIBUS/CANopen/DeviceNet
communication
10: Ethernet communication
11: High-speed pulse HDIB
12: Pulse train AB
13: EtherCAT/PROFINET/EtherNet IP
communication
14: Programmable expansion card
15: Multi-step speed run
16: Reserved
-148-
Function parameters
Default Modify
50.00Hz
0.00Hz