Download Print this page

INVT Goodrive350-19 Series Operation Manual page 184

Vfd for crane
Hide thumbs Also See for Goodrive350-19 Series:

Advertisement

Goodrive350-19 Series VFD for Crane
Function
Name
code
Low-frequency
P04.23
oscillation control
factor of motor 2
High-frequency
P04.24
oscillation control
factor of motor 2
Oscillation control
P04.25
threshold of motor 2
P04.26
Energy-saving run
Voltage setting
P04.27
channel
Description
the rigidity of the mechanical characteristics of
the motor. You need to calculate the rated slip
frequency of the motor as follows:
△f=f
Of which, f
is the rated frequency of the motor
b
2, corresponding to function code P12.02. n is
the rated rotating speed of the motor 2,
corresponding to the function code P12.03. p is
the number of pole pairs of the motor. 100.0%
corresponds to the rated slip frequency △f of
motor 2.
Setting range: 0.0–200.0%
In space voltage vector control mode, the
motor, especially the large-power motor, may
experience
current
frequencies, which may cause unstable motor
running, or even VFD overcurrent. You can
adjust the two function codes properly to
eliminate such phenomenon.
Setting range of P04.23: 0–100
Setting range of P04.24: 0–100
Setting range of P04.25: 0.00Hz–P00.03 (Max.
output frequency)
0: Disable
1: Automatic energy-saving run
In light-load state, the motor can adjust the
output voltage automatically to achieve energy
saving.
0: Keypad (determined by P04.28)
1: AI1
2: AI2
3: AI3
4: HDIA
5: Multi-step running
(The setting is determined by related
parameters in group P10.)
6: PID
7: Modbus/Modbus TCP communication
-172-
-n*p/60
b
oscillation
at
certain
Function parameters
Default Modify
10
10
30.00Hz
0
0

Advertisement

loading
Need help?

Need help?

Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel