Goodrive350-19 Series VFD for Crane
Function
Name
code
Enabling auto
P08.55
carrier frequency
reduction
Min. carrier
P08.56
frequency
Temperature point
of auto carrier
P08.57
frequency
reduction
Interval of carrier
P08.58
frequency
reduction
AI1 disconnection
P08.59
detection threshold
AI2 disconnection
P08.60
detection threshold
AI3 disconnection
P08.61
detection threshold
Output current filter
P08.62
time
Output torque filter
P08.63
times
24V power supply
card power-on
P08.64
delay
Current filtering
times in coordinate
P08.65
change
Motor parameter
P08.66
autotuning
Description
0: Disable
1: Enable
Note: Automatic carrier frequency reduction
indicates that the VFD automatically
reduces the carrier frequency when
detecting the heat sink temperature exceeds
the rated temperature. When the
temperature decreases to a specified value,
the carrier frequency restores to the setting.
This function can reduce the VFD overheat
alarm reporting chances.
1.0–15.0kHz
40.0–85.0° C
0–30min
0–100%
0–100%
0–100%
0.000–10.000s
0–8
0.000–5.000s
0–3
0: No operation
1: Power-on dynamic autotuning 1
-208-
Function parameters
Default Modify
○
0
●
Model
depended
○
70.0° C
○
10min
○
0%
○
0%
○
0%
○
0.000s
○
8
○
0.000s
○
0
○
0
Need help?
Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?