Goodrive350-19 Series VFD for Crane
Function
Name
code
Power display
calibration
P12.28
coefficient of motor
Parameter display
P12.29
of motor 2
System inertia of
P12.30
motor 2
Speed control
P12.31
switchover mode of
motor 2
Group P13—SM control
Function
Name
code
SM injected-current
P13.00
decrease ratio
Detection mode of
P13.01
initial pole
1h
1min
Setting range: 20.0%–150.0%
0.00–3.00
2
0: Display by motor type
In this mode, only parameters related to the
present motor type are displayed.
1: Display all
In this mode, all the motor parameters are
displayed.
0–30.000kgm
0: No switchover, which indicates keeping
consistent with P00.00 of motor 1
1: Switch to SVC1
2: Switch to VF
3: Switch to FVC
Used to set the reduction rate of the input
reactive current. When the active current of the
synchronous motor increases to some extent,
the input reactive current can be reduced to
improve the power factor of the motor.
Setting range: 0.0%–100.0% (of the motor
rated current)
0: No detection
1: High frequency superposition
Description
Time t
Motor overload multiples
116 %
200 %
2
Description
-229-
Function parameters
Default Modify
○
1.00
○
0
0.000
○
2
kgm
◎
0
Default Modify
○
80.0%
◎
0
Need help?
Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?