Goodrive350-19 Series VFD for Crane
Function
Name
code
DP communication
P15.25
timeout period
CANopen
P15.26
communication
timeout period
CANopen
communication
P15.27
baud rate
Master/slave CAN
communication
P15.28
address
Master/slave CAN
communication
P15.29
baud rate
Master/slave CAN
communication
P15.30
timeout period
DeviceNET
communication
P15.31
timeout period
(reserved)
Display node baud
P15.32
rate
P15.33
Enabling polling
Instance number of
P15.34
polling output
Description
(PZD2–PZD12 correspond to P14.60–P14.70)
0.0–60.0s
0.0–60.0s
0–7
0: 1000K bps
1: 800K bps
2: 500K bps
3: 250K bps
4: 125K bps
5: 100K bps
6: 50K bps
7: 20K bps
0–127
0: 50K bps
1: 100K bps
2: 125K bps
3: 250K bps
4: 500K bps
5: 1M bps
0.0 (invalid)–60.0s
0.0–60.0s
0–65535
0–1
19–27
19: INVT VFD output
20: ODVA basic speed control output
21: ODVA extended speed control output
22: ODVA speed and torque control output
23: ODVA extended speed and torque control
-239-
Function parameters
Default Modify
○
1.0s
○
1.0s
◎
3
◎
1
◎
2
○
0.0s
○
1.0s
●
0
○
1
○
19