Goodrive350-19 Series VFD for Crane
Fault
Fault type
code
[85] Output current
Cuu
imbalance
PtcE
overtemperature fault
E-OvL
[87] Overload fault
E-OS
[88] Overspeed fault Motor overspeed.
E-dS
[89] Stalling fault
E-AI1
[92] AI1 disconnection AI1 is disconnected.
[93] AI2 disconnection AI2 is disconnected.
E-AI2
E-AI3
[94] AI3 disconnection AI3 is disconnected.
[95]
E-EIP
communication
timeout
[96]
E-PAO
bootloader
[97] Second channel
ENC2O
encoder disconnection
[98] SSI position
ENCPI
deviation fault
[99] SSI position
E-PUP
forward limit position
3PH output current
imbalance.
[86] PTC
Ambient temperature too
high.
Load too heavy.
Motor suffers stalling.
No data transmission
EtherNet
IP
between the communication
card and the host controller
(or PLC).
No
upgrade
The burned file does not
contain a bootloader.
Second channel encoder
disconnection
A position sensor position
feedback exception occurred
during positioning.
The position feedback from
the position sensor has
exceeded the maximum
software limit position.
Possible cause
-358-
Troubleshooting
Solution
Check the load wiring with UVW.
Check whether the value of
P92.32 is too small.
Check the ambient temperature.
Check whether load is too
heavy.
Check
whether
(Mechanism overload protection
point) is too small.
Check whether P92.34 is too
small.
Check whether the brake can be
opened properly.
Check whether P92.36 is too
small.
Check AI1 wiring.
Check AI2 wiring.
Check AI3 wiring.
Check whether the
communication card wiring is
loose or dropped.
Burn the file with a bootloader
again.
You can screen out this fault by
setting P14.12. (The absence of
a bootloader does not affect the
normal running of machine.)
Check
the
second
encoder wiring.
Check
whether
feedback
from
the
sensor to P17.60 and P17.61 is
normal.
Check whether the feedback
from the position sensor is
proper.
Check whether the maximum
P92.46
channel
the
data
position