Goodrive350-19 Series VFD for Crane
Function
Name
code
AO1 output lower
P06.17
limit
AO1 output
P06.18
corresponding to
lower limit
AO1 output upper
P06.19
limit
AO1 output
P06.20
corresponding to
upper limit
P06.21
AO1 output filter
Description
EtherCAT/PROFINET/EtherNet IP
communication (0–1000)
22: Torque current (bipolar, 0–Triple the motor
rated current)
23: Exciting current (bipolar, 0–Triple the motor
rated current)
24: Set frequency (bipolar, 0–Max. output
frequency)
25: Ramp reference frequency (bipolar, 0–Max.
output frequency)
26: Rotational speed (bipolar, 0–Speed
corresponding to max. output frequency)
27: Value 2 set through
EtherCAT/PROFINET/EtherNet IP
communication (0–1000)
28: C_AO1 from the programmable card (Set
P27.00 to 1.) (0–1000)
29: C_AO2 from the programmable card (Set
P27.00 to 1.) (0–1000)
30: Rotational speed (0–Twice the motor rated
synchronous speed)
31: Output torque (Actual value, 0–Twice the
motor rated torque)
32: AIAO detected temperature output
33–34: Reserved
35: Hook rope length (0–Max. rope length)
36–63: Reserved
The function codes define the relationship
between the output value and analog output.
When the output value exceeds the allowed
range, the output uses the lower limit or upper
limit.
When the analog output is current output, 1mA
equals 0.5V.
In different cases, the corresponding analog
output of 100% of the output value is different.
-190-
Function parameters
Default Modify
○
0.0%
○
0.00V
○
100.0%
○
10.00V
○
0.000s