Goodrive350-19 Series VFD for Crane
Function
Name
code
Sequence of
switching
P07.03
running-command
channels by
pressing QUICK
Stop function
P07.04
validity of
STOP/RST
Selection 1 of
parameters
P07.05
displayed in
running state
Selection 2 of
parameters
P07.06
displayed in
running state
Selection of
parameters
P07.07
displayed in
stopped state
P07.08
Frequency display 0.01–10.00
Description
0: No function
1: Jog
2: Reserved
3: Switch between forward and reverse rotating
4: Clear the UP/DOWN setting
5: Coast to stop
6: Switch command channels in sequence
7: Quick commissioning mode (based on
non-factory parameter settings)
Tens place: Reserved
When P07.02=6, set the sequence of switching
running-command channels by pressing this
key.
0: Keypad→Terminal→Communication
1: Keypad←→Terminal
2: Keypad←→Communication
3: Terminal←→Communication
Used to specify the stop function validity of
STOP/RST. For fault reset, STOP/RST is valid
in any conditions.
0: Valid only for keypad control
1: Valid both for keypad and terminal control
2: Valid both for keypad and communication
control
3: Valid for all control modes
0x0000–0xFFFF
0x0000–0xFFFF
0x0000–0xFFFF
-193-
Function parameters
Default Modify
0
0
0x03FF
0x0000
0x00FF
1.00