Function
Name
code
Forward current
P04.41
setting in I/F mode
for AM 1
Proportional
P04.42
coefficient in I/F
mode for AM 1
Integral coefficient
P04.43
in I/F mode for AM 1
Starting frequency
P04.44
for switching off I/F
mode for AM 1
Enabling I/F mode
P04.45
for AM 2
Description
When I/F control is adopted for AM 1, this
parameter is used to set the output current. The
value is a percentage in relative to the rated
current of the motor.
Setting range: 0.0–200.0%
When I/F control is adopted for AM 1, this
parameter is used to set the proportional
coefficient of the output current in closed-loop
control.
Setting range: 0–5000
When I/F control is adopted for AM 1, this
parameter is used to set the integral coefficient
of the output current in closed-loop control.
Setting range: 0–5000
When I/F control is adopted for AM 1, this
parameter is used to set the starting frequency
for switching off the output current closed-loop
control. When the output frequency is lower
than the value of this parameter, the current
closed-loop control in the I/F control mode is
enabled; and when the output frequency is
higher than P04.50, the current closed-loop
control in the I/F control mode is disabled.
Output
frequency
P04.50
P04.44
Output
current
P04.41/P
04.52
Setting range: 0.00–20.00Hz
0: Invalid
1: Enable
-175-
Function parameters
Default Modify
120.0%
350
150
10.00Hz
0