Goodrive350-19 Series VFD for Crane
Function
Name
code
Voltage set through
P04.28
keypad
Voltage increase
P04.29
time
Voltage decrease
P04.30
time
P04.31 Max. output voltage The function codes are used to set the upper
P04.32 Min. output voltage
Weakening
coefficient in
P04.33
constant power
zone
Pull-in current 1 in
P04.34
SM V/F control
Description
8: PROFIBUS/CANopen/DeviceNet
communication
9: Ethernet communication
10: HDIB
11: EtherCAT/PROFINET/EtherNet IP
communication
12: Programmable expansion card
13: Reserved
The function code is the voltage digital setting
when "keypad" is selected as the voltage
setting channel.
Setting range: 0.0%–100.0%
Voltage increase time means the time needed
for the VFD to accelerate from min. output
voltage to the max. output frequency.
Voltage decrease time means the time needed
for the VFD to decelerate from the max. output
frequency to min. output voltage.
Setting range: 0.0–3600.0s
and lower limits of output voltage.
Vmax
V set
Vmin
t1
Setting range of P04.31: P04.32–100.0% (of
the motor rated voltage)
Setting range of P04.32: 0.00Hz–P04.31
1.00–1.30
When the SM VF control mode is enabled, the
function code is used to set the reactive current
of the motor when the output frequency is lower
-173-
Function parameters
t1=P04.29
t2=P04.30
t2
Time t
Default Modify
100.0%
5.0s
5.0s
100.0%
0.0%
1.00
20.0%