Goodrive350-19 Series VFD for Crane
Function
Name
code
Duty ratio
P91.39
corresponding to
frequency f0
P91.40
Frequency f1
Duty ratio
P91.41
corresponding to
frequency f1
P91.42
Frequency f2
Duty ratio
P91.43
corresponding to
frequency f2
P91.44
Frequency f3
Duty ratio
P91.45
corresponding to
frequency f3
P91.46
Frequency f4
Duty ratio
P91.47
corresponding to
frequency f4
HDO carrier
P91.48
frequency
HDO closing delay
P91.49
during stop
Pre-torque input
P91.50
signal source and
effective period
Description
output frequency)
Setting range of P91.40: P91.42–P91.38
Setting range of P91.42: P91.44–P91.40
Setting range of P91.44: P91.46–P91.42
Setting range of P91.46: 0.00Hz–P91.44
P91.39, P91.41, P91.43, P91.47 setting range:
0.0%–100.0%
Segmented adjustment is performed based on
the cycle ratio and frequency.
Duty cycle
P91.39
P91.41
P91.43
P91.45
P91.47
P91.46
P91.44
P91.42
Note: The HDO output polarity is specified
by P06.05.
0.5–10.0kHz
0–100.0s
0x00–0x17
Ones place: Input signal source
0: Invalid
1: AI1
2: AI2
3: Modbus
4: Internally given
5:
PROFIBUS/CANopen/PROFINET
communication
6: Reserved
7: Keypad
Tens place: Pre-torque action effective period
0: During brake release in VFD brake control
1: When the given pre-torque changes
Note (when the tens place is 1):
-321-
P91.40
P91.38
Frequency
Function parameters
Default Modify
100.0%
40.00Hz
80.0%
20.00Hz
40.0%
10.00Hz
20.0%
0.00Hz
0.0%
1.0kHz
5.0s
0x00