Goodrive350-19 Series VFD for Crane
Function
Name
code
Description
S
REV
ln
OFF→ON
ON
ON→OFF
ON
ON
ON→OFF
OFF
S
: Three-wire control; FWD: Forward running;
ln
REV: Reverse running
3: Three-wire control 2. This mode defines S
as the enabling terminal, and the running
command is generated by FWD or REV, but the
direction is controlled by both FWD and REV.
During running, the S
closed, and terminal REV or FWD generates a
rising edge signal, then the VFD starts to run in
the direction set by the state of terminal; the
VFD needs to be stopped by disconnecting
terminal S
. The stop method is specified by
In
P01.08.
SB1
SB2
SB3
S
FWD
ln
OFF→ON
ON
ON
ON
OFF
ON→OFF
-
S
: Three-wire control; FWD: Forward running;
ln
REV: Reverse running.
Note: For two-wire controlled running mode,
when the FWD/REV terminal is valid, if the
-182-
Previous
Present
direction
direction
FWD run REV run
REV run FWD run
REV run FWD run
FWD run REV run
Stop
terminal needs to be
In
FWD
S
ln
REV
COM
Running
REV
direction
ON
FWD run
OFF
FWD run
REV run
OFF→ON
REV run
-
Stop
Function parameters