Goodrive350-19 Series VFD for Crane
Function
Name
code
AO1 output
P06.14
selection
HDO high-speed
P06.16
pulse output
Description
0: Running frequency (0–Max. output
frequency)
1: Set frequency (0–Max. output frequency)
2: Ramp reference frequency (0–Max. output
frequency)
3: Rotational speed (0–Speed corresponding to
max. output frequency)
4: Output (0–Twice the inverter unit rated
current)
5: Output current (0–Twice the motor rated
current)
6: Output (0–1.5 times the inverter unit rated
voltage)
7: Output power (0–Twice the motor rated
power)
8: Set torque (0–Twice the motor rated torque)
9: Output torque (Absolute value, 0–±Twice the
motor rated torque)
10: AI1 input (0–10V/0–20mA)
11: AI2 input (0–10V)
12: AI3 input (0–10V/0–20mA)
13: HDIA input (0.00–50.00kHz)
14: Value 1 set through Modbus/Modbus TCP
communication (0–1000)
15: Value 2 set through Modbus/Modbus TCP
communication (0–1000)
16: Value 1 set through
PROFIBUS/CANopen/DeviceNet
communication (0–1000)
17: Value 2 set through
PROFIBUS/CANopen/DeviceNet
communication (0–1000)
18: Value 1 set through Ethernet
communication (0–1000)
19: Value 2 set through Ethernet
communication (0–1000)
20: HDIB input (0.00–50.00kHz)
21: Value 1 set through
-189-
Function parameters
Default Modify
○
0
○
0