Goodrive350-19 Series VFD for Crane
Function
Name
code
P00.00 Speed control mode
Channel of running
P00.01
commands
P05.00
HDI input type
P05.01
Function of S1
P05.02
Function of S2
Speed
P20.15
measurement mode
P25.03
Function of S7
P25.04
Function of S8
HDIA high-speed
P05.38
pulse input function
selection
HDIB high-speed
P05.44
pulse input function
selection
Enabling height
P93.08
measuring
Table 5-6 Parameters about external measuring (HDI)
0: SVC 0
1: SVC 1
2: Space voltage vector control mode
3: Closed-loop vector control mode
Note: Before using a vector control mode (0, 1,
or 3), enable the VFD to perform motor
parameter autotuning first.
0: Keypad
1: Terminal
2: Communication
0x00–0x11
Ones place: HDIA input type
0: HDIA is high-speed pulse input
1: HDIA is digital input
Tens place: HDIB input type
0: HDIB is high-speed pulse input
1: HDIB is digital input
1: Run forward
2: Run reversely
0: Measuring speed by PG card/Measuring height
locally
64: Limit of forward run (upward)
65: Limit of reverse run (downward)
2: Input set through encoder, used together with
HDIB
2: Input set through encoder, used together with
HDIA
0–1
0: Disable
1: Enable internal measuring (motor encoder) (In
closed-loop mode, the encoder measures the speed
and height.)
2: Enable external measuring (HDI) (In open- and
closed-loop modes, the pulley encoder measures
Description
-83-
Commissioning guidelines
Setting
2
1
0x00
1
2
0
64
65
2
2
2
Need help?