Download Print this page

INVT Goodrive350-19 Series Operation Manual page 506

Vfd for crane
Hide thumbs Also See for Goodrive350-19 Series:

Advertisement

Goodrive350-19 Series VFD for Crane
autotuning interface, you can press
16:02:35
Fwd
Local
Ready
Parameter groups
User defined parameters
State monitoring
Motor parameter autotune
Copy parameter/Restore default
System settings
Back
Home
After selecting a motor autotuning type, enter motor parameter autotuning interface, and press RUN
key to start motor parameter autotuning. After autotuning is done, a message will pop up indicating
autotuning is succeeded, and then it will return to the main interface of stop. During autotuning, you
can press STOP/RST key to terminate autotuning; if any fault occur during autotuning, the keypad will
display a fault interface.
16:02:35
Autotune steps:0
Autotuning parameters...
D.3.2.9 Backing up parameters
You can choose Menu > Copy parameter/Restore default, and press
key to enter the function parameter backup interface and function parameter restoration interface to
upload/download VFD parameters, or restore VFD parameters to default values. The keypad has
three different storage areas for parameter backup, and each storage area can save the parameters
of one VFD, which means the keypad can save parameters of three VFDs in total.
16:02:35
Fwd
Local
Ready
Parameter groups
User defined parameters
State monitoring
Motor parameter autotune
Copy parameter/Restore default
System settings
Back
Home
D.3.2.10 System settings
You can choose Menu > System settings, and press
system setting interface to set the keypad language, time/date, backlight brightness, backlight time
and restore parameters.
Note: Clock battery is not included, and the keypad time/date needs to be reset after power off.
16:02:35
GD350-19
Ensure motor nameplate parameters are set
correctly.
Sele
Figure D-18 Parameter autotuning operation
Fwd
Local
Run
Back
Home
Figure D-19 Parameter autotuning finished
GD350-19
16:02:35
MemArea 1: BACKUP01
MemArea
MemArea
Restore default (excl motor para)
Restore default (test mode)
Restore default (incl motor para)
Sele
Back
Figure D-20 Parameter backup
key or
key to return to the previous menu.
Fwd
Local
Ready
GD350-19
Back
Home
OK
GD350-19
16:02:35
Fwd
Autotune steps:3
Parameters autotuned
...
OK
Back
Fwd
Local
Ready
GD350-19
2: BACKUP02
3: BACKUP03
Home
Sele
-494-
Optional peripheral accessories
16:02:35
Fwd
Complete para rotary autotune
Complete para static autotune
Partial para static autotune
Complete para rotary autotune 2 (for AM)
Partial para static autotune 2 (for AM)
Back
Local
Run
GD350-19
Home
OK
key,
Fwd
16:02:35
Upload local func para to keypad
Download all func para from keypad
Download NonMotor func para from keypad
Download motor func para from keypad
Back
key,
key or
Local
Ready
GD350-19
Home
OK
key or
Local
Ready
GD350-19
Home
OK
key to enter

Advertisement

loading
Need help?

Need help?

Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?