Goodrive350-19 Series VFD for Crane
Note:
At certain faults that cannot be reset, such as VFD internal hardware damaged, zero servo
cannot be entered. At the faults that can be reset, with zero servo conditions met, zero servo can
be entered.
Every time zero servo is exited, torque verification is not performed only at the first running
command giving, which means the verification is performed at all the following running command
giving.
When P93.02 ones place=2, the motor becomes hot, the fan cannot be mounted at the same
shaft as the motor, and it must be independently controlled.
The following faults cannot be reset:
Fault code
OUt1
Inverter unit U-phase protection
OUt2
Inverter unit V-phase protection
OUt3
Inverter unit W-phase protection
UV
N
Fault?
Y
N
Voltage
recovered?
Y
Zero-servo run
Run or jog command?
Y
P93.07 tens
place=1?
Y
Exit zero-servo run
Fault type
Bus undervoltage fault
Stop
Y
Stop detection
pulses > P93.05?
Y
Fault reset
Overvoltage?
N
N
Hardware fault?
N
Down command?
Y
Fault code
ETH1
ETH2
STO
STL1
-71-
Commissioning guidelines
N
Y
Stop
Fault type
To-ground short-circuit fault 1
To-ground short-circuit fault 2
Safe torque off
Exception occurred to safe circuit
of channel 1
Need help?