Goodrive350-19 Series VFD for Crane
Function
Name
code
Motor overload
P17.37
count value
P17.38 Process PID output -100.0%–100.0%
Function codes in
P17.39
parameter
download error
P17.40 Motor control mode
Electromotive
P17.41
torque upper limit
Braking torque
P17.42
upper limit
Forward rotation
upper-limit
P17.43
frequency in torque
control
Reverse rotation
upper-limit
P17.44
frequency in torque
control
Inertia
P17.45
compensation
torque
Description
indicates it is in the generating state while a
negative value indicates it is in the motoring
state.
Range: -3000.0Nm–3000.0Nm
0–65535
0.00–99.00
Ones place: Control mode
0: Vector 0
1: Vector 1
2: Space voltage vector control
3: Closed-loop vector control
Tens place: Control status
0: Speed control
1: Torque control
2: Position control
Hundreds place: Motor number
0: Motor 1
1: Motor 2
2: Motor 3
0.0%–300.0% (of the motor rated current)
0.0%–300.0% (of the motor rated current)
0.00Hz–P00.03
0.00Hz–P00.03
-100.0%–100.0%
-253-
Function parameters
Default Modify
●
0
●
0.00%
●
0.00
●
0x2
●
180.0%
●
180.0%
●
50.00Hz
●
50.00Hz
●
0.0%
Need help?