Goodrive350-19 Series VFD for Crane
Function
Name
code
Reference object of
P00.08
B frequency
command
Combination mode
P00.09
of setting source
Set frequency via
P00.10
keypad
P00.11
ACC time 1
P00.12
DEC time 1
P00.13
Running direction
Carrier frequency
P00.14
setting
Description
0: Max. output frequency
1: A frequency command
0: A
1: B
2: (A+B)
3: (A- B)
4: Max(A, B)
5: Min. (A, B)
When A and B frequency commands select the
keypad for setting, the value of the function
code is the original setting one of the frequency
data of the VFD.
Setting range: 0.00Hz–P00.03 (Max. output
frequency)
ACC time means the time needed if the VFD
speeds up from 0Hz to the max. output
frequency (P00.03).
DEC time means the time needed if the VFD
speeds down from the max. output frequency
(P00.03) to 0Hz.
The VFD has four groups of ACC/DEC time,
which can be selected by P05. The factory
default ACC/DEC time of the VFD is the first
group.
P00.11 and P00.12 setting range: 0.0–3600.0s
0: Run at the default direction.
1: Run at the opposite direction.
2: Disable reverse running.
Note: It can be modified only when P11.26 is
1 indicating special functions are enabled.
Carrier
Electro magnetic
frequency
noise
1kHz
High
10kHz
15kHz
Low
-149-
Noise and leakage
Cooling
current
level
Low
High
High
Function parameters
Default Modify
○
0
○
0
○
50.00Hz
Model
○
depended
Model
○
depended
○
0
Low
Model
○
depended