Goodrive350-19 Series VFD for Crane
Function
code
P90.19
Reverse brake closing frequency
5.1.4 Commissioning lifting applications in mine hoists, winches, and drawworks
5.1.4.1 Common wiring
R
S
T
Lifting
Lowering
Upper limit
Fault reset
Figure 5-2 Wiring for applications in mining hoists, winches, and drawworks (recommended analog
Name
Braking resistor
(+)
R
S
VFD
T
S1
S2
S3
S4
COM
PW
+24V
+10V
AI1
GND
reference 0V–10V)
Setting
1.50Hz
PB
U
V
W
PE
PWR
PWR
PGND
PGND
A1+
A1+
A1-
A1-
B1+
B1+
B1-
B1-
Z1+
Z1+
Z1-
Z1-
PG card
PG card
RO1A
RO1B
RO1C
RO2A
RO2B
RO2C
-64-
Commissioning guidelines
Remarks
/
M
3~
PG
PG
Closed-
loop
vector
Brake
output
VFD fault
output
Need help?