Goodrive350-19 Series VFD for Crane
Function
Name
code
V/F frequency point
P04.07
3 of motor 1
V/F voltage point 3
P04.08
of motor 1
V/F slip
P04.09
compensation gain
of motor 1
Low-frequency
P04.10
oscillation control
factor of motor 1
High-frequency
P04.11
oscillation control
Description
Output voltage
100.0%
V
b
V3
V2
V1
f1
Setting range of P04.03: 0.00Hz–P04.05
Setting range of P04.04: 0.0%–110.0% (of the
rated voltage of motor 1)
Setting range of P04.05: P04.03–P04.07
Setting range of P04.06: 0.0%–110.0% (of the
rated voltage of motor 1)
Setting range of
(Rated frequency of AM 1) or P04.05– P02.16
(Rated frequency of SM 1)
Setting range of P04.08: 0.0%–110.0% (of the
rated voltage of motor 1)
Used to compensate for the motor rotating
speed change caused by load change in the
space voltage vector mode, and thus improve
the rigidity of the mechanical characteristics of
the motor. You need to calculate the rated slip
frequency of the motor as follows:
△f=f
Of which, f
is the rated frequency of the motor
b
1, corresponding to function code P02.02. n is
the rated rotating speed of the motor 1,
corresponding to the function code P02.03. p is
the number of pole pairs of the motor. 100.0%
corresponds to the rated slip frequency △f of
motor 1.
Setting range: 0.0–200.0%
In space voltage vector control mode, the
motor, especially the large-power motor, may
experience
current
frequencies, which may cause unstable motor
running, or even VFD overcurrent. You can
-170-
Output
frequency(Hz)
f2 f3
f
b
P04.07: P04.05–P02.02
-n*p/60
b
oscillation
at
certain
Function parameters
Default Modify
0.00Hz
00.0%
0.0%
10
10

Advertisement