Renesas M16C/64A Series User Manual page 682

Table of Contents

Advertisement

M16C/64A Group
28.2
Registers
Table 28.3
Registers
Address
03D8h
D/A0 Register
03DAh
D/A1 Register
03DCh
D/A Control Register
28.2.1
D/Ai Register (DAi) (i = 0, 1)
D/Ai Register (i = 0, 1)
b7
28.2.2
D/A Control Register (DACON)
D/A Control Register
b7 b6 b5 b4
b3
b2
b1
R01UH0136EJ0210 Rev.2.10
Jul 31, 2012
Register
Symbol
b0
DA0
DA1
Output value of D/A conversion
b0
Symbol
DACON
Bit Symbol
Bit Name
DA0E
D/A0 output enable bit
DA1E
D/A1 output enable bit
No register bits. If necessary, set to 0. The read values are undefined.
(b7-b2)
Symbol
DA0
DA1
DACON
Address
03D8h
03DAh
Function
Address
03DCh
0 : Output disabled
1 : Output enabled
0 : Output disabled
1 : Output enabled
28. D/A Converter
Reset Value
00h
00h
00h
Reset Value
00h
00h
Setting Range
RW
00h to FFh
RW
Reset Value
00h
Function
RW
RW
RW
Page 649 of 800

Advertisement

Table of Contents
loading