M16C/64A Group
Table 19.11
Registers and Settings in Three-Phase Mode 0 (2/2)
Register
TA0S
TA1S
TA2S
TA3S
TABSR
TA4S
TB0S
TB1S
TB2S
TMOD1 to
TMOD0
MR0
TA1MR,
MR1
TA2MR,
TA4MR
MR2
MR3
TCK1 to TCK0 Select a count source.
TMOD1 to
TMOD0
MR1 to MR0
TB2MR
MR3
TCK1 to TCK0 Select a count source.
PCLKR
PCLK0
TACS0 to
7 to 0
TACS2
TBCS1
TCS3 to TCS0 Select a count source.
TAPOFS
POFSi
UDF
TAiP
i = 1, 2, 4
Note:
1.
This table does not describe a procedure.
R01UH0136EJ0210 Rev.2.10
Jul 31, 2012
Bit
Not used for three-phase motor control timer.
Set to 1 when starting counting, and to 0 when stopping counting.
Set to 1 when starting counting, and to 0 when stopping counting.
Not used for three-phase motor control timer.
Set to 1 when starting counting, and to 0 when stopping counting.
Not used for three-phase motor control timer.
Not used for three-phase motor control timer.
Set to 1 when starting counting, and to 0 when stopping counting.
Set to 10b (one-shot timer mode).
Set to 0.
Set to 0.
Set to 1 (select a trigger by setting bits TAiTGH and TAiTGL).
Set to 0.
Set to 00b (timer mode).
Set to 00b.
4
Set to 0.
Set to 0.
Select a count source.
Select a count source.
Set to 0.
Set to 0.
19. Three-Phase Motor Control Timer Function
(1)
Function and Setting
Page 349 of 800