Renesas M16C/64A Series User Manual page 641

Table of Contents

Advertisement

M16C/64A Group
26.3.6
Transmission
26.3.6.1
Transmit Signal Timing Select
Rising or falling timing of the transmit signal can be selected.
The rising timing of the transmit signal is selected by bits CRISE2 to CRISE0 in the CECC4 register.
Figure 26.12 shows Rising Timing of Transmit Signal.
CRISE2 to CRISE0 = 110b: standard value - 180 μ s
Figure 26.12 Rising Timing of Transmit Signal
The falling timing of the transmit signal is selected by bits CFALL1 to CFALL0 in the CECC4 register.
Figure 26.13 shows Falling Timing of Transmit Signal.
CFALL1 to CFALL0 = 11b: standard value - 160 μ s
10b: standard value - 100 μ s
01b: standard value - 40 μ s
CFALL1 to CFALL0 = 11b: standard value - 310 μ s
10b: standard value - 250 μ s
01b: standard value - 190 μ s
Figure 26.13 Falling Timing of Transmit Signal
R01UH0136EJ0210 Rev.2.10
Jul 31, 2012
CEC output
101b: standard value - 150 μ s
100b: standard value - 120 μ s
011b: standard value - 90 μ s
010b: standard value - 60 μ s
001b: standard value - 30 μ s
Start bit
CEC output
Data bit
CEC output
26. Consumer Electronics Control (CEC) Function
000b:
standard value
111b:
standard value + 30 μ s
00b:
standard value
00b:
standard value
Page 608 of 800

Advertisement

Table of Contents
loading

Table of Contents