Renesas M16C/64A Series User Manual page 474

Table of Contents

Advertisement

M16C/64A Group
Table 22.19 Registers and Setting Values in Input Capture Mode (Simultaneous Count Operation) (1/2)
Register
PMCiCON0
PMCiCON1
PMCiCON2
PMCiCON3
BFULFLG
PMCiSTS
PTHDFLG
PTD0FLG
PTD1FLG
i = 0, 1
-: Unimplemented bits in PMC1
Note:
1.
This table does not describe a procedure.
R01UH0136EJ0210 Rev.2.10
Jul 31, 2012
Bit
Set to 1. (Refer to 22.3.5.1 "Setting
EN
Procedure").
SINV
Select input signal polarity.
FIL
Select filter enabled/disabled.
EHOLD
Set to 0.
HDEN
Set to 0.
SDEN
Set to 0.
DRINT0
Set to 00b.
DRINT1
TYP0
Select measuring object.
TYP1
CSS
Set to 1.
EXSDEN
Set to 0.
EXHDEN
Set to 0.
Flag indicating PMCi
ENFLG
operated/stopped.
INFLG
Input signal flag
CEFLG
Counter overflow flag
Set to 1 when using counter
CEINT
overflow interrupt.
PSEL0
Set to 01b.
PSEL1
CRE
Set to 1.
CFR
Set to 1.
CST
Set to 1.
PD
Set to 1.
CSRC0
Set to 00b
CSRC1
CDIV0
Set to 00b.
CDIV1
CPFLG
Not used (read as undefined value)
REFLG
Not used (read as undefined value) Not used (read as undefined value)
DRFLG
Not used (read as undefined value) Not used (read as undefined value)
Not used (read as undefined value)
Not used (read as undefined value) Not used (read as undefined value)
Not used (read as undefined value) Not used (read as undefined value)
Not used (read as undefined value) Not used (read as undefined value)
SDFLG
Not used (read as undefined value)
Function
PMC0
Set to 1. (Refer to 22.3.5.1 "Setting
Procedure").
Select input signal polarity.
Select filter enabled/disabled.
Set to 0.
Select measuring object.
Not used.
Input signal flag
Counter overflow flag
Set to 1 when using counter
overflow interrupt.
Set to 10b.
Set to 1.
Set to 1.
Set to 1.
Set to 1.
Select clock source.
Select count source divisor.
22. Remote Control Signal Receiver
PMC1
-
-
-
-
-
-
-
-
-
Page 441 of 800
(1)

Advertisement

Table of Contents
loading

Table of Contents