Commissioning (software)
6.5 Additional information on configuring the SINAMICS Integrated
6.5.8
Current controller cycle clocks <> 125 µs / use of output cams and measuring
inputs
If current controller cycle clocks <> 125 µs are used, the parameter calculations of the drive
must be transferred to the PG when using cam outputs on the TM15 / TM17 High Feature or
for global measuring inputs, and FastIO configuration generated again.
A change of the current controller cycle clock may have effects on the sampling times of the
inputs/outputs on the drive side (e.g. TM15/TM17 High Feature, p4099 Sampling time of the
inputs/outputs).
Sampling times <> 125 µs occur in the following cases:
● For servo drives with manual change of the current controller sampling time (drive
● For vector drives depending on the number of vector drives and with chassis units
● If only an infeed and no drives are connected to the drive unit, then the sampling time is
For the cam outputs and the measuring input inputs (only for global measuring inputs) to
function correctly, the sampling times must be known to the engineering system.
Table 6- 8
Cam outputs
Measuring input inputs
(global measuring
inputs)
Measuring input inputs
(local measuring
inputs)
In order that the changed cycle clock ratios are taken into account by the the engineering
system, proceed as follows:
1. Go online and perform a project download. The SINAMICS performs parameter
2. Perform an upload to the PG ("Target system" > Load" > "Load CPU / drive unit to PG").
3. This transfers the parameter calculations of the drive to the PG. The cycle clock ratios are
4. Go offline.
224
parameters p0112 and p0115[0])
depending on the device type used
250 µs
Influence of the current controller cycle clock on the dead time compensation
Current controller cycle clock has no
effect on the function
SIMOTION D
D4x5-2 (terminal X142)
---
calculations once. These are automatically backed up on the CompactFlash card.
then known in the engineering system.
Current controller cycle clock has an
effect on the function
TM15 / TM17 High Feature
TM15 / TM17 High Feature
SIMOTION D (except D4x5-2,
terminal X142)
Controller extension (CX)
SINAMICS S110/S120 control
units
---
Commissioning and Hardware Installation Manual, 02/2012
SIMOTION D4x5-2