Parameter List - Siemens SINAMICS V60 Getting Started

Controlled power module
Hide thumbs Also See for SINAMICS V60:
Table of Contents

Advertisement

3.2

Parameter list

Par. No.
Name
P01
Parameter write protection
0: Sets all parameters other than P01 as read-only parameters.
1: Sets all parameters to be both readable and writable.
P01 automatically resets to 0 after power-on!
P05
Internal enable
0: JOG mode can be enabled externally.
1: JOG mode can be enabled internally.
P05 automatically resets to 0 after power-on!
P16
Maximum motor current
This parameter specifies the maximum motor current (2 x rated motor current) of your choice.
P20
Speed loop proportional gain 0.01-5.00 Depends on drive
Factory defaults:
4 Nm: 0.81(0.54); 6 Nm: 1.19(0.79); 7.7 Nm: 1.50(1.00); 10 Nm: 2.10(1.40)
Note:
Default value varies with software version.
This parameter specifies the proportional gain (K
The bigger the value, the higher the gain and rigidity. The setting depends on specific drive and load.
Generally, the bigger the load inertia, the bigger the value is to set. If however, there is no oscillation occurred
in the system, you can set the value as big as possible.
P21
Speed loop integral time
constant
Factory defaults:
4 Nm: 17.7(44.2); 6 Nm: 17.7(44.2); 7.7 Nm: 17.7(44.2); 10 Nm: 18.0(45.0)
Note:
Default value varies with software version.
This parameter specifies the integral action time (T
The smaller the value, the higher the gain and rigidity. The setting depends on specific drive and load.
P26
Maximum motor speed
Sets the maximum possible motor speed.
P30
Position loop proportional
gain
1. This parameter specifies the proportional gain of position loop.
2. The bigger the value, the higher both the gain and rigidity, and at the same pulse command frequency the
smaller the position hysteresis. However, excessively high value setting may cause system oscillation or
overshooting.
3. The setting depends on specific drive and load.
P31
Position loop feedforward
gain
1. This parameter specifies the feedforward gain of position loop.
2. Setting the value to 100 % means position hysteresis is always 0 at any pulse command frequency.
3. Increasing the feedforward gain of position loop improves the high-speed response characteristics of the
control system, but meanwhile causes the system's position loop unstable and liable to oscillation.
4. Unless very high response characteristics are necessary, set the feedforward gain of position loop to 0.
P34
Maximum following error
Controlled Power Module (CPM60.1)
A5E03975175-002, 04/2014
Range
Default
0 - 1
0
0-1
0
0-100
100
version
, proportional component) of speed control loop.
p
0.1-300.0 Depends on drive
version
, integral component) of speed control loop.
n
0-2200
2200
0.1-3.2
3.0(2.0)
0-100
85(0)
20-999
500
Increment
Unit
1
-
1
-
1
%
0.01
Nm*s/rad
0.1
ms
20
rpm
0.1
1000/min
1
%
1
100 pulses Immediately
Effective
Immediately
Immediately
Power On
Immediately
Immediately
Power On
Immediately
Immediately