Data Communication with the PLC
Default settings
4-8
Following a new start or a RESET of the module, the parameter area is set
with the default values specified in table 4-4.
Table 4-4

Default values for the parameter area

Data record 0
Byte 0
Byte 1
Data record 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14
Byte 15
Value
00
No diagnostics and wire break monitoring
H
00
Alarms disabled
H
01
Sensor 1:
H
Counter 1 to measuring point 1
C
1
00
H
00
Resolution of 0.1 mm; rising edge starts/stops
H
counter; counter starts immediately with sent
START pulse; measuring cycle time is
16 msec.
02
Sensor 2:
H
C
Counter 2 to measuring point 1
2
00
H
00
Same as byte 4
H
03
Sensor 3:
H
C
Counter 3 to measuring point 1
3
00
H
00
Same as byte 4
H
04
Sensor 4:
H
Counter 4 to measuring point 1
C
4
00
H
00
Same as byte 4
H
00
Cycle time of 16 msec
H
00
No synchronous mode
H
Meaning
i
i 1
i
i 1
i
i 1
i
i 1
SM 338 Equipment Manual
(4) J31069-D401-U1-A0-7618