Replacement Of Cabling, Axis 5 Motor - ABB IRB 6640 Foundry Prime Product Manual

Table of Contents

Advertisement

4.3.2 Replacement of cabling, axis 5 motor

Location of cabling
The separate cables for the axis 5 motor are located inside the upper arm tube, as
shown in the figure below.
xx0500002294
A
B
Required equipment
Equipment
Cable harness axis 5
Circuit diagram
Standard toolkit
Other tools and procedures may
be required. See references to
these procedures in the step-by-
step instructions below.
Removal, cabling axis 5 motor
The procedure below details how to remove the cabling from the axis 5 motor.
1
Product manual - IRB 6640 Foundry Prime
3HAC040586-001 Revision: N
Motor axis 5 with connectors R4.FB5 and R4.MP5
Connectors R3.FB5 and R3.MP5
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
Before entering the robot working area.
© Copyright 2011-2018 ABB. All rights reserved.