ABB IRB 6640 Foundry Prime Product Manual page 292

Table of Contents

Advertisement

4 Repair
4.5.1 Replacing the SMB unit
Continued
3
4
5
6
7
8
9
292
Action
Remove the SMB unit as detailed in
unit on page 289
Refit the new SMB unit according to step 3 - 6 in
Refitting, SMB unit on page 290
Note
Make sure that the gasket under the SMB cover is
not damaged!
Secure the SMB cover with its attachment screws.
Apply rust preventive on the surface around the
SMB cover and under/on top of the screw heads.
Perform a leakdown test according to
air hoses (Foundry Prime) on page
Update the revolution counter.
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further de-
tailed in the section
First test run may cause injury
or damage on page
29.
© Copyright 2011-2018 ABB. All rights reserved.
Note
Removing, SMB
Inspection of
155.
See
Updating revolution counters
on page
Product manual - IRB 6640 Foundry Prime
3HAC040586-001 Revision: N
444.