ABB IRB 6640 Foundry Prime Product Manual page 403

Table of Contents

Advertisement

6
7
8
Product manual - IRB 6640 Foundry Prime
3HAC040586-001 Revision: N
Action
Replace the two screws temporarily used
to secure the protection pipe, with two
stainless attachment screws M6x16.
Apply Mercasol on surfaces as shown in
the figure.
Install a new cable guide by pressing it
down into position as shown in the figure.
Note
The cable guide shall be locked in position
by the groove.
© Copyright 2011-2018 ABB. All rights reserved.
4.7.1 Replacing gearbox axis 1
Note
View from below.
xx1000000369
A: Attachment screws (2 pcs)
B: Protection pipe
xx1000000370
A: Mercasol
B: Protection pipe
C: Sealing ring
xx1000000371
A: Groove
B: Cable guide
C: Protection pipe
D: Center tube
Continues on next page
4 Repair
Continued
403

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents