ABB IRB 6640 Foundry Prime Product Manual page 335

Table of Contents

Advertisement

Unloading the balancing device
The procedure below details how to use the press tool in order to unload the
balancing device. How to remove the press tool, is detailed in section
the balancing device using a hydraulic press tool on page
1
2
3
4
5
6
7
8
9
10
Product manual - IRB 6640 Foundry Prime
3HAC040586-001 Revision: N
4.5.4.5 Unloading the balancing device using hydraulic press tool
Action
Fit the moving pin to the current press device.
Fit the correct press device and moving pin
to the press tool. Secure with the bolt, press
device.
Note
Make sure the bolt is secured properly!
Remove the rear cover of the balancing
device, by unscrewing the attachment screws.
DANGER
DO NOT! remove any other screws then the
rear cover attachment screws.
Fit the press tool to the rear of the balancing
device with enclosed bolts. Tighten them
properly!
Fit the hydraulic cylinder to the press tool.
Connect the hydraulic pump to the cylinder.
Increase the pressure and press until the
marking on the moving pin indicates the cor-
rect position (in level with the pressure block).
Turn the fix plate to position "Closed" in order
to lock the tool in loaded condition.
Unload the hydraulic cylinder.
The hydraulic cylinder may now be removed
from the tool, when necessary.
© Copyright 2011-2018 ABB. All rights reserved.
336.
Note
Choose the correct press device, accord-
ing to the table
Using the correct press
device on page
334.
The moving pin is shown in the figure
Press tool and hydraulic cylinder on
page
333.
Shown in the figure
Press tool and hy-
draulic cylinder on page
333.
xx0700000422
E: Rear cover attachment screws,
4 pcs
Art. no. is specified in
Required equip-
ment on page
334.
See the figure
Press tool and hydraulic
cylinder on page
333.
Art. no. is specified in
Required equip-
ment on page
334.
See the figure
Press tool and hydraulic
cylinder on page
333.
Art. no. is specified in
Required equip-
ment on page
334.
See the figure
Press tool and hydraulic
cylinder on page
333.
Do not apply more pressure than neces-
sary, it could damage bearings and
sealings at the shaft.
See the figure
Press tool and hydraulic
cylinder on page
333.
4 Repair
Continued
Restoring
335

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents