Calibrating Header Sensors; Calibrating Header Height Sensor - MacDon M155 Unloading And Assembly Instructions

Self-propelled windrower
Table of Contents

Advertisement

7.6 Calibrating Header Sensors

When a new header is attached to the windrower, the header's sensors must be calibrated using the cab display module
(CDM) so that their output can be correctly interpreted by the windrower control module (WCM).

7.6.1 Calibrating Header Height Sensor

The header height sensor can be calibrated by accessing the cab display module's (CDM) WINDROWER SETUP menu. The
calibration procedure must be completed for the sensor to be correctly calibrated.
NOTE:
• The header must be attached to the windrower to perform this procedure. The CDM automatically selects the header
profile based on the type of attached header.
• The engine must be running to perform this procedure.
DANGER
Ensure that all bystanders have cleared the area.
To calibrate the header height sensor:
1. Start the engine.
2. Press PROGRAM (A) and SELECT (B) on the CDM to enter
programming mode.
• WINDROWER SETUP? will appear on the upper line.
3. Press SELECT (B) until CALIBRATE SENSORS? appears on the
upper line.
• NO/YES will appear on the lower line.
4. Press right arrow (B) to select YES. Press SELECT (C).
• TO CALIBRATE SELECT will appear on the upper line.
5. Press left arrow (A) or right arrow (B) until HEADER HEIGHT
appears on the lower line. Press SELECT (C).
• CALIBRATING HEIGHT will appear on the upper line.
• RAISE HEADER HOLD will appear on the lower line.
262320
CAB DISPLAY MODULE
MXXX
A
Figure 7.83: CDM Programming Buttons
MXXX
A
Figure 7.84: Header Height Calibration
242
WINDROWER SETUP?
CXXX
NO/YES
CALIBRATING HEIGHT
CXXX
RAISE HEADER HOLD
B
C
B
Revision A

Advertisement

Table of Contents
loading

Table of Contents