23.5.3 Alarm Profile Editing
23.5.3 Alarm Profile Editing
Table 23-6
item in the profile column (such as Default).
Table 23-6
Button
Store
Rename
Clone
Reset
Remove
23.5.4 Alarm Severity Options
To change or assign alarm severity, left-click the alarm severity you want to change in the alarm profile
column. Seven severity levels appear for the alarm:
Inherited and Use Default severity levels only appear in alarm profiles. They do not appear when you
view alarms, history, or conditions.
23.5.5 Row Display Options
In the network or node view, the Alarm Profiles window (Alarm Profile Editor for Node view) displays
three check boxes at the bottom of the window:
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
23-10
lists and describes the five profile-editing options available when you right-click an alarm
Alarm Profile Editing Options
Description
Saves a profile in a node or in a file.
Changes a profile name.
Creates a profile that contains the same alarm severity settings as the profile being cloned.
Restores a profile to its previous state or to the original state (if it has not yet been applied).
Removes a profile from the table editor.
Not Reported (NR)
Not Alarmed (NA)
Minor (MN)
Major (MJ)
Critical (CR)
Use Default
Inherited
Only show service-affecting severities—If unchecked, the editor shows severities in the format
sev1/sev2 where sev1 is a service-affecting severity and sev2 is not service-affecting. If checked, the
editor only shows sev1 alarms.
Hide reference values—Highlights alarms with nondefault severities by clearing alarm cells with
default severities.
Hide identical rows—Hides rows of alarms that contain the same severity for each profile.