Appendix C
DWDM Administrative and Service States
Table C-5
ONS 15454 Optical Payload Port Service State Transitions (continued)
Current Service State
OOS-AU,AINS (ANSI)
Unlocked-disabled,automaticInService
(ETSI)
OOS-AU,AINS & FLT (ANSI)
Unlocked-disabled,automaticInService &
failed (ETSI)
OOS-AU,FLT (ANSI)
Unlocked-disabled,failed (ETSI)
August 2005
Action
All required OCHNC
connections exist.
Put the port in the OOS,MT
(ANSI) or Locked,maintenance
(ETSI) administrative state.
Put the port in the OOS,DSBLD
(ANSI) or Locked,disabled
(ETSI) administrative state.
Alarm/condition is raised.
Alarm/condition is cleared.
Put the port or cross-connect in
the IS (ANSI) or Unlocked
(ETSI) administrative state.
Put the port or cross-connect in
the OOS,DSBLD (ANSI) or
Locked,disabled (ETSI)
administrative state.
Put the port or cross-connect in
the OOS,MT (ANSI) or
Locked,maintenance (ETSI)
administrative state.
Alarm/condition is cleared.
Put the port or cross-connect in
the IS,AINS (ANSI) or
Unlocked,automaticInService
(ETSI) administrative state.
Put the port or cross-connect in
the OOS,DSBLD (ANSI) or
Locked,disabled (ETSI)
administrative state.
Put the port or cross-connect in
the OOS,MT (ANSI) or
Locked,maintenance (ETSI)
administrative state.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
C.3.2 Optical Payload Port Service State Transitions
Next Service State
IS-NR (ANSI)
Unlocked-enabled (ETSI)
OOS-MA,MT (ANSI)
Locked-enabled,maintenance (ETSI)
OOS-MA,DSBLD (ANSI)
Locked-enabled,disabled (ETSI)
OOS-AU,AINS & FLT (ANSI)
Unlocked-disabled,automaticInService &
failed (ETSI)
OOS-AU,AINS (ANSI)
Unlocked-disabled,automaticInService
(ETSI)
OOS-AU,FLT (ANSI)
Unlocked-disabled,failed (ETSI)
OOS-MA,DSBLD (ANSI)
Locked-enabled,disabled (ETSI)
OOS-AUMA,FLT & MT (ANSI)
Locked-disabled,failed & maintenance
(ETSI)
IS-NR (ANSI)
Unlocked-enabled (ETSI)
OOS-AU,AINS & FLT (ANSI)
Unlocked-disabled,automaticInService &
failed (ETSI)
OOS-MA,DSBLD (ANSI)
Locked-enabled,disabled (ETSI)
OOS-AUMA,FLT & MT (ANSI)
Locked-disabled,failed & maintenance
(ETSI)
C-7