DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch Web UI Reference Guide
Log Description
Log Message: <interface-id> recover from BPDU under protection state.
Parameters description:
interface-id: Interface on which detected STP BPDU attack.
CFM
Log Description
Event description: Cross-connect is detected
Log Message: CFM cross-connect. VLAN:<vlanid>, Local(MD Level:<mdlevel>,
Port <[unitID:]portNum>, Direction:<mepdirection>) Remote(MEPID:<mepid>,
MAC:<macaddr>)
Parameters description:
vlanid: Represents the VLAN identifier of the MEP.
mdlevel: Represents the MD level of the MEP.
unitID: Represents the ID of the device in the stacking system.
portNum: Represents the logical port number of the MEP.
mepdirection: Can be "inward" or "outward".
mepid: Represents the MEPID of the MEP. The value 0 means unknown
MEPID.
macaddr: Represents the MAC address of the MEP. The value all zeros
mean unknown MAC address.
Note: In CFM hardware mode, remote MEP information (mepid and
macaddr) is unknown.
Event description: Error CFM CCM packet is detected
Log Message: CFM error ccm. MD Level:<mdlevel>, VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>) Remote(MEPID:<mepid>,
MAC:<macaddr>)
Parameters description:
vlanid: Represents the VLAN identifier of the MEP.
mdlevel: Represents MD level of the MEP.
unitID: Represents the ID of the device in the stacking system.
portNum: Represents the logical port number of the MEP.
mepdirection: Can be "inward" or "outward".
mepid: Represents the MEPID of the MEP. The value 0 means unknown
MEPID.
macaddr: Represents the MAC address of the MEP. The value all zeros
means unknown MAC address.
Note: In CFM hardware mode, remote MEP information (mepid and
macaddr) is unknown.
Event description: cannot receive the remote MEP's CCM packet
Log Message: CFM remote down. MD Level:<mdlevel>, VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>)
Parameters description:
vlanid: Represents the VLAN identifier of the MEP.
mdlevel: Represents the MD level of the MEP.
unitID: Represents the ID of the device in the stacking system.
portNum: Represents the logical port number of the MEP.
mepdirection: Represents the MEP direction, which can be "inward" or