Additional System Components; Terminal Module Tm54F; Description - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components

9.1

Terminal Module TM54F

9.1.1

Description

The TM54F Terminal Module is a terminal expansion module for snapping onto a mounting
rail according to EN 60715. The TM54F offers safe digital inputs and outputs for controlling
SINAMICS Safety Integrated functions.
The TM54F must be directly connected to the PPU of SINUMERIK 828D via DRIVE-CLiQ. In
so doing, the topology rules (Page 121) must be observed.
TM54F features the following interfaces:
Table 9- 1
Type
DRIVE-CLiQ interfaces
Fail-safe digital inputs (F-DI)
Fail-safe digital outputs (F-DO)
Sensor
Sensor
Digital inputs for testing the F-DO at test stop
Power supply
Sensors: Fail-safe devices to issue commands and sense - for example, Emergency Stop buttons
1)
and safety locks, position switches and light arrays/light curtains.
Forced checking procedure: The sensor power supply is cycled on and off by the TM54F when the
2)
forced checking procedure is active for the sensors, cable routing, and the evaluation electronics.
The TM54F has 10 fail-safe digital inputs and 4 fail-safe digital outputs.
A fail-safe digital input comprises:
● 2 digital inputs
A fail-safe digital output comprises:
● Output switching to 24 V
● Output switching to ground
● Digital input to check the switching state
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7
Interface overview of the TM54F
power supplies, dynamization supported
1)
power supply, no dynamization
1)
2)
9
Number
2
10
4
2
1
4
1
189