Removing The Devicenet Master - ABB IRB 14000 Product Manual

Hide thumbs Also See for IRB 14000:
Table of Contents

Advertisement

Removing the DeviceNet master

Opening the computer
1
2
3
4
5
Removing the DeviceNet master
1
2
Product manual - IRB 14000
3HAC052983-001 Revision: D
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
WARNING - The unit is sensitive to ESD!
on page 55
(Depending on which connection is installed)
Disconnect the connector:
Profibus/S: A32.2
Ethernet/IP/S: A32.1
ProfiNet/S: A32.3
Open the computer unit by removing the attach-
ment screws and lift the cover off.
CAUTION
Be careful not to stretch the fan cable.
Disconnect the fan connector.
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
WARNING - The unit is sensitive to ESD!
on page 55
© Copyright 2015 - 2016 ABB. All rights reserved.
4.7.15 Replacing the DeviceNet master
Note
xx1300000684
A
Attachment screw (4 pcs)
B
Cover
Note
Continues on next page
4 Repair
Continued
A
B
397

Hide quick links: