Action
Orient the motor correctly and fit it into the
arm. Secure with the screws.
CAUTION
The motor must be inserted gently. If the
gears do not mate, rotate the axis carefully
back and forth until the gears are mated.
Reconnect the motor connectors.
R1.MP2R / R1.MP2L
R1.FB2R / R1.FB2L
© Copyright 2015 - 2016 ABB. All rights reserved.
4.4.2 Replacing the axis-2 motor
Note
Motor orientation: orient the motor accord-
ing to the figure below, in regard to the
encircled motor connector.
xx1500000566
Screws: 3HAB3409-212
Tightening torque: cross-tighten all screws
to 1 Nm first, then final cross-tighten to 3
Nm.
xx1400002613
Continues on next page
4 Repair
Continued