Removing the expansion board complete
1
2
3
4

Refitting the expansion board complete

Use this procedure to refit the expansion board complete.
Refitting the expansion board complete
1
Product manual - IRB 14000
3HAC052983-001 Revision: D
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
WARNING - The unit is sensitive to ESD!
on page 55
Remove the attachment screws on the computer
unit.
Grip the expansion board and gently pull it straight
out.
CAUTION
Always grip the expansion board around the
edges to avoid damage to the board or its com-
ponents.
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
© Copyright 2015 - 2016 ABB. All rights reserved.
4.7.14 Replacing the expansion board complete
Note
A
xx1300000859
A
Attachment screw (2 pcs)
Note
4 Repair
Continued
Continues on next page
385