2 Installation and commissioning

2.4.2 Connecting power and the FlexPendant

2.4.2 Connecting power and the FlexPendant
Overview
The following illustration shows the connectors on the right side of the controller.
xx1500000503
Q1
XS4
XP0

Connecting power supply

Line fusing

Line fusing of the IRB 14000 is 5A at 100-240 V.

Rated power

Rated power of the IRB 14000 is 360 W.
Required equipment
Equipment
Power supply cable (single phase)
External circuit breaker
External earth fault protection at control cables 3 -15m
External earth fault protection at control cables >15m
Circuit diagram
Continues on next page
90
Power switch
FlexPendant
Power input
Main AC power connector, IEC 60320-1 C14, 100-240 VAC, 50-60 Hz
© Copyright 2015 - 2016 ABB. All rights reserved.
Note
8A
30mA
300mA
See Circuit diagram - IRB 14000.
Product manual - IRB 14000
3HAC052983-001 Revision: D