Removing the capacitor bank
Use this procedure to remove the capacitor bank.
Pulling the controller out partially
1
2
3
4
Product manual - IRB 14000
3HAC052983-001 Revision: D
Action
DANGER
Turn off all:
•
electric power supply
•
air pressure supply
to the robot, before starting the repair work on the
robot.
Remove the body cover.
ELECTROSTATIC DISCHARGE (ESD)
The equipment is sensitive to ESD. Before hand-
ling the equipment please read the safety inform-
ation in the section
WARNING - The unit is sens-
itive to ESD! on page 55
Remove the attachment screws that fasten the
controller to the body.
Put a trolley beneath the controller.
© Copyright 2015 - 2016 ABB. All rights reserved.
4.7.3 Replacing the capacitor bank
Note
Flange screw (10 pcs)
xx1500000525
xx1500000303
xx1500000364
Continues on next page
4 Repair
Continued
315