4
Closing the computer
1
2
3
4
Product manual - IRB 14000
3HAC052983-001 Revision: D
Action
Fit the DeviceNet master board by pushing it into
the socket on the motherboard.
CAUTION
Always grip the board around the edges to avoid
damage to the board or its components.
Refit the attachment screw on the DeviceNet
master bracket.
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
WARNING - The unit is sensitive to ESD!
on page 55
Connect the fan connector.
CAUTION
Be careful not to stretch or squeeze the fan cable.
Fasten the computer cover with its attachment
screws.
© Copyright 2015 - 2016 ABB. All rights reserved.
4.7.15 Replacing the DeviceNet master
Note
xx1500000728
A
Attachment screw
B
DeviceNet master board
Note
xx1300000684
A
Attachment screw (4 pcs)
B
Cover
Continues on next page
4 Repair
Continued
A
B
399