4 Repair
4.4.2 Replacing the axis-2 motor
Continued
4
5
Continues on next page
162
Action
Tighten the set screw.
Axis 1, axis 2, axis 3 and axis 7.
Axis 4, axis 5 and axis 6.
Remove the fixture.
© Copyright 2015 - 2016 ABB. All rights reserved.
Note
Screw: M3-set screw (1 pc).
Tightening torque: 0.6 Nm.
xx1500000518
Screw: M2-set screw (2 pcs).
Tightening torque: 0.2 Nm.
xx1500001648