Removing The Right Arm's Drive Board - ABB IRB 14000 Product Manual

Hide thumbs Also See for IRB 14000:
Table of Contents

Advertisement

Removing the right arm's drive board

Use this procedure to remove the drive board.
Pulling the controller out partially
1
2
3
4
Product manual - IRB 14000
3HAC052983-001 Revision: D
Action
DANGER
Turn off all:
electric power supply
air pressure supply
to the robot, before starting the repair work on the
robot.
Remove the body cover.
ELECTROSTATIC DISCHARGE (ESD)
The equipment is sensitive to ESD. Before hand-
ling the equipment please read the safety inform-
ation in the section
WARNING - The unit is sens-
itive to ESD! on page 55
Remove the attachment screws that fasten the
controller to the body.
Put a trolley beneath the controller.
© Copyright 2015 - 2016 ABB. All rights reserved.
4.7.9 Replacing the right arm's drive board
Note
Flange screw (10 pcs)
xx1500000525
xx1500000303
xx1500000364
Continues on next page
4 Repair
Continued
355