4 Repair
4.7.5 Replacing the power distribution board
Continued
4
5
6
Refitting the power distribution board
Use this procedure to refit the power distribution board.
Refitting the power distribution board
1
2
3
4
Continues on next page
328
Action
Loosen the left attachment screw and remove the
right attachment screw.
Slide the power distribution board to the right.
Lift the power distribution board out.
Action
Place the power distribution board and slide it to
the left.
Tighten the left attachment screw and refit the
right attachment screw.
Connect the connectors:
•
G2.X8 (X8)
•
G2.XS2 (X2)
•
G2.XS1 (X1)
•
G2.XS3 (X3)
•
G2.XS6 (X6)
•
G2.XS5 (X5)
•
G2.XS7 (X7)
•
G2.XS4 (X4)
Put two cable ties around the plate and the G2.X8
connector.
© Copyright 2015 - 2016 ABB. All rights reserved.
Note
xx1500000308
Note
DSQC 662 Power distribution
board: 3HAC026254-001
Screws: M3x6 (2 pcs).
Tightening torque: 0.9 Nm.
xx1500000308
Product manual - IRB 14000
3HAC052983-001 Revision: D