Removing The Expansion Board Complete; Removing The Fieldbus Adapter - ABB IRB 14000 Product Manual

Hide thumbs Also See for IRB 14000:
Table of Contents

Advertisement

Removing the expansion board complete

Use this procedure to remove the expansion board complete.

Removing the fieldbus adapter

1
2
3
4
Product manual - IRB 14000
3HAC052983-001 Revision: D
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
WARNING - The unit is sensitive to ESD!
on page 55
(Depending on which connection is installed)
Disconnect the connector:
Profibus/S: A32.2
Ethernet/IP/S: A32.1
ProfiNet/S: A32.3
Loosen the attachment screws (2 pcs) on front of
the fieldbus adapter to release the fastening
mechanism.
Note
Do not remove the attachment screws, only loosen
them.
© Copyright 2015 - 2016 ABB. All rights reserved.
4.7.14 Replacing the expansion board complete
Note
xx0700000193
A Attachment screw (2 pcs)
B Fastening mechanism
4 Repair
Continued
Continues on next page
383