Siemens G130 List Manual page 1611

Hide thumbs Also See for G130:
Table of Contents

Advertisement

A07920
Drive: Torque/speed too low
Message value:
-
Message class:
Application/technological function faulted (17)
Drive object:
VECTOR_G
Component:
Motor
Reaction:
NONE
Acknowledge:
NONE
Cause:
The torque deviates from the torque/speed envelope characteristic (too low).
See also: p2181 (Load monitoring response)
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
A07921
Drive: Torque/speed too high
Message value:
-
Message class:
Application/technological function faulted (17)
Drive object:
VECTOR_G
Component:
Motor
Reaction:
NONE
Acknowledge:
NONE
Cause:
The torque deviates from the torque/speed envelope characteristic (too high).
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
A07922
Drive: Torque/speed out of tolerance
Message value:
-
Message class:
Application/technological function faulted (17)
Drive object:
VECTOR_G
Component:
Motor
Reaction:
NONE
Acknowledge:
NONE
Cause:
The torque deviates from the torque/speed envelope characteristic.
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
F07923
Drive: Torque/speed too low
Message value:
-
Message class:
Application/technological function faulted (17)
Drive object:
VECTOR_G
Component:
Motor
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The torque deviates from the torque/speed envelope characteristic (too low).
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
F07924
Drive: Torque/speed too high
Message value:
-
Message class:
Application/technological function faulted (17)
Drive object:
VECTOR_G
Component:
Motor
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The torque deviates from the torque/speed envelope characteristic (too high).
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Propagation:
GLOBAL
Propagation:
GLOBAL
Propagation:
GLOBAL
Propagation:
GLOBAL
Propagation:
GLOBAL
4 Faults and alarms
4.2 List of faults and alarms
1611

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents