Toshiba e-STUDIO206L Service Manual page 575

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

Error code
Classification
C410
Fuser unit related
service call
C411
C412
C430
C440
C443
C445
C447
C449
C450
C452
C4B0
C4C0
C550
Optional
communication
related service call
C551
C570
C580
C5A0
Circuit related
service call
C8E0
Optional
communication
related service call
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Contents
Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO206L/256/306/356/456/506 only)
Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO207L/257/307/357/457/507 only)
Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO207L/257/307/357/457/507 only)
Thermistor abnormality: Abnormality of the thermistor is
detected after a specified period of time has passed from
power-ON (including ready state).
(e-STUDIO206L/256/306/356/456/506 only)
Fuser roller abnormality: The temperature of the fuser
roller has exceeded the range of control or does not even
reach the range.
(e-STUDIO206L/256/306/356/456/506 only)
Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO207L/257/307/357/457/507 only)
Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO207L/257/307/357/457/507 only)
Thermistor or heater abnormality: Abnormality of service
call the thermistor is detected or the temperature of the
fuser roller does not rise in a specified period of time.
(e-STUDIO207L/257/307/357/457/507 only)
Fuser roller abnormality: The temperature of the fuser
roller has exceeded the range.
(e-STUDIO207L/257/307/357/457/507 only)
Thermistor abnormality during printing: Abnormality of the
thermistor is detected during printing.
Thermistor abnormality at ready state: Abnormality of the
thermistor is detected during ready state.
Fuser unit error counter abnormality
Fuser unit new/old detection fuse abnormality
RADF I/F error: Communication error has occurred
between the RADF and the scanner.
Document feeder model detection error: An optional
document feeder that is not compatible to this equipment
is installed.
Communication error between Engine-CPU and CNV
board
Communication error between CNV board and finisher
EEPROM communication abnormality (LGC board)
ADF communication abnormality: The system has to be
stopped because the control abnormality occurred
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
8 - 15
Troubleshooting
P. 8-141
P. 8-141
P. 8-141
P. 8-142
P. 8-142
P. 8-144
P. 8-144
P. 8-144
P. 8-145
P. 8-146
P. 8-146
P. 8-147
P. 8-147
P. 8-148
P. 8-148
P. 8-148
P. 8-149
P. 8-151
P. 8-149
ERROR CODE AND TROUBLESHOOTING
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents